Shaftwall

Base layer 1″ x 24″ ToughRock® Shaftliner or DensGlass® Shaftliner panels between 2-1/2″ floor and ceiling J runners with T section of 2-1/2″ steel C-H, C-T or I-studs between panels.

Opposite side: Base layer 1/2″ (12.7 mm) ToughRock® Fireguard C® gypsum board or 1/2″ (12.7 mm) DensArmor Plus® Firegaurd C® gypsum panels applied at right angles to studs with 1″ Type S screws 24″ o.c. and 6″ from floor or ceiling. Face layer 1/2″ (12.7 mm) ToughRock® Fireguard C® gypsum board or 1/2″ (12.7 mm) DensArmor Plus® Fireguard C® gypsum panels applied at right angles to studs with 1-5/8″ Type S screws 12″ o.c. and 3″ from floor and ceiling runners. Joints offset 24″ from base layer joints. (NLB) Sound tested with 1-1/2″ glass fiber insulation friction fit in stud space.

Hourly Rating: 2-hour
STC Rating: 50-54 STC
Fire Test Reference: ITS Design GP/WA 120-01,GA WP 7054.4
Sound Test Reference: RAL TL09-360, 12-08-09
Approved for Assembly:
DensGlass® Shaftliner Panel
ToughRock® Fireguard C® Products
DensArmor Plus® Fireguard C® Products
ToughRock® Shaftliner