FILTERS Arrow
Content Type
  • resource
  • faq
  • product
Division
  • Gypsum
    • Exterior Roof
    • Exterior Walls
    • Interior
Brand
  • DensDeck®
  • DensGlass®
  • ToughRock®
Area of Application
  • Exterior
  • Interior
  • Roof
Benefits
  • Ease-of-Use
  • Fire Rated
  • Fire Resistant
  • Hail Resistant
  • High Impact Resistant
  • Lightweight
  • Moisture Resistant
  • Special Applications
  • Versatility
  • Wind Uplift Resistant
Building Type
  • Commercial
  • Multi-Family
Showing 16 results
Georgia-Pacific ToughRock Fireguard 45Georgia-Pacific ToughRock Fireguard 45 Fire-Rated Gypsum Board
Thickness

nominal inches: 1/2″ (12.7 mm), ± 1/64″ (0.4 mm)

Width

nominal: 4′ (1220 mm), – 3/32” (2.4 mm); 54″ (1372 mm), – 3/32” (2.4 mm)

Length

standard: 88′ (2440 mm) to 16′ (4880 mm) ± 1/4″ (6.4 mm)

Weight

lbs./sq. ft. nominal (kg/m2): 1.65 (8.1)1

R Value

°F•ft2•hr/BTU (m2•K/W): 0.45 (0.08)2

Humidified Deflection

5/16″ (8 mm)

1Represents approximate weight for design and shipping purposes. Actual weight may vary depending on manufacturing location and other factors. 2Per Gypsum Association document GA-235.

Fire Resistance
Special Application

ToughRock FireGuard X Fire-Rated Type X Gypsum Board
Thickness

nominal inches: 5/8″ (15.9 mm), ± 1/64″ (0.4 mm)

Width

nominal: 4′ (1220 mm), 54” (1372 mm), 60″ (1524 mm) ± 3/32″ (2.4 mm)

Length

standard: 8′ (2440 mm) to 14′ (4270 mm), ± 1/4″(6.4 mm)

Weight

lbs./sq. ft., nominal (kg/m²) 2.2 (10.7)1

R Value

ft2•°F•hr/BTU (m2•K/W): 0.56 est. (0.10)

Humidified Deflection

max: 5/8” (16 mm)2

1Represents approximate weight for design and shipping purposes. Actual weight may vary depending on manufacturing location and other factors. 2Specified minimum values are as defined in ASTM C1396.

Fire Resistance

Georgia-Pacific ToughRock FireGuard Fire-Rated Type C Gypsum Board
Thickness

nominal inches: 5/8″ (15.9 mm), ±1/64″ (0.4 mm)

Width

nominal: 4′ (1220 mm) ±3/32″ (2.4 mm)

Length

standard: 8′ (2440 mm) to 14′ (4270 mm), ±1/4″ (6.4 mm)

Weight

lbs./sq. ft., nominal (kh/m²): 2.3 (11.2)1

R Value

ft2•°F•hr/BTU (m2•K/W): 0.56 est. (0.10)

1Represents approximate weight for design and shipping purposes. Actual weight may vary depending on manufacturing location and other factors.

Fire Resistance

Thickness

nominal inches: 5/8″ (15.9 mm) ± 1/64″ (0.4 mm)

Width

nominal: 54″ (1372 mm) ± 3/32″ (2.4 mm)

Length

standard: 8′ (2440 mm) to 14′ (4270 mm) ± 1/4″ (6.4 mm)

Weight

lbs./sq. ft., nominal (kg/m²): 2.2 (10.7)1

R Value

ft2•°F•hr/BTU (m2•K/W): 0.56 est. (0.10)2

Humidified Deflection

max: 5/8″ (16 mm)3

1Represents approximate weight for design and shipping purposes. Actual weight may vary depending on manufacturing location and other factors. 2Per Gypsum Association document GA-235. 3Specified minimum values are as defined in ASTM C1396.

Fire Resistance
Special Applications

ToughRock Lightweight Fire-rated Drywall Gypsum Wallboard
Thickness

5/8″ (15.9 mm)

Width

4’ (1220 mm), 54” (1372 mm), 60” (1524 mm) ± 3/32” (2.4 mm)

Length

8′ – 14′ (2440-4270 mm)

Weight

2.0 (9.0) lbs./sq. ft., nominal (kg/sq.m)1

R-Value

°F•ft2•hr/BTU (m2•K/W): 0.56 est. (0.10)

Humidified Deflection

5/8” (16 mm)2

1Represents approximate weight for design and shipping purposes. Actual weight may vary depending on manufacturing location and other factors. 2Specified minimum values are as defined in ASTM C1396.

Fire Resistance
Light Weight Applications

ToughRock Fireguard C Fire-Rated Gypsum Soffit Board
Thickness

nominal inches: 5/8” (15.9 mm), ± 1/64” (0.4 mm)

Width

nominal: 4’ (1220 mm) ± 3/32” (2.4 mm)

Length

standard: 8’ (2440 mm) to 12’ (3658 mm) ± ¼” (6.4 mm)

Weight

lbs./sq. ft., nominal (kg/m²) 2.2 (10.7)

R Value

ft2•°F•hr/BTU (m2•K/W): 0.56 est. (0.10)

Humidified Deflection

4/8” (12 mm)

1Represents approximate weight for design and shipping purposes. Actual weight may vary depending on manufacturing location and other factors. 2Per Gypsum Association document GA-235.

Fire Resistance
Special Applications

ToughRock Shaftliner Fire-Rated Drywall, Assembly Panels
Thickness

nominal inches2: 1″ (25.4 mm), ± 1/32″(0.8 mm)

Width

Nominal2: 24″ (610 mm) – 3/32″(2.4 mm)

Length

standard2: 8′ (2440 mm) to 12′ (3658 mm) ± 1/4″ (6.4 mm)

Weight

lbs./sq. ft., nominal (kg/m²): 4 (19.5)1

1Represents approximate weight for design and shipping purposes. Actual weight may vary depending on manufacturing location and other factors. 2Specified minimum values are as defined in ASTM C1396.

Fire Resistance
Special Applications

ToughRock FireGuard X Mold Guard Moisture-Resistant Gypsum Board Drywall Panels
Thickness

nominal inches: 5/8” (15.9 mm) ± 1/64” (0.4 mm)

Width

nominal: 4′ (1220 mm), 54″ (1372 mm)

Length

standard: 8 ft. (2440 mm) – 14′ (4270 mm)

Weight

lbs/sq. ft. nominal (kg/m²): 2.3 (11.2)1

R Value

°F•ft2•hr/BTU (m2•K/W): 0. .56 est. (0.10)2

Humidified Deflection

5/8″ (16 mm)3

1Represents approximate weight for design and shipping purposes. Actual weight may vary depending on manufacturing location and other factors. 2Per Gypsum Association document GA-235. 3Specified minimum values are as defined in ASTM C1396.

Fire Resistance
Moisture Resistance

ToughRock Gypsum Sheathing Panels
Thickness

nominal inches: 1/2″ (12.7 mm), ± 1/32″ (0.8 mm)3

Width

nominal: 4′ (1220 mm), – 1/8″ (3 mm)3

Length

standard: 8’ (2440 mm) ± 1/4″ (6.4 mm)3

Weight

lbs/sq. ft. nominal (kg/m²): 1.7 (9)1

R Value

0.45 (0.079)2

Humidified Deflection

10/8″ (32 mm)

Versatility
Fire Resistant

Thickness

nominal inches: 1/2″ (12.7 mm) ± 1/64″ (0.4 mm)

Width

nominal: 4′ (1220 mm), – 3/32″ (2.4 mm)

Length

standard: 8′ (2440 mm) ± 12′ (3658 mm) ± 1/4″ (6.4 mm)

Weight

lbs./sq. ft., nominal (kg/m2): 1.7 (7.8)1

R Value

°F•ft2•hr/BTU (m2•K/W): 0.45 (0.08)2

Humidified Deflection

10/8″ (32 mm)

Special Application
Fire Resistant
Versatility

DensGlass Shaftliner Fire-Rated Reinforced Fiberglass Wall Panels
Thickness

1″ (25.4 mm) ± 1/32″ (0.8 mm)

Width

Nominal: 24″ (610 mm)

Length

standard: 8′ (2440 mm), 12′ (3658 mm) ± 1/4″ (6 mm)2

Weight

lbs/sq. ft. nominal (kg/m²): 4.0 (20)4

R Value

ft2•°F•hr/BTU (m2•K/W): > 0.65 (0.115)3

1Tested in accordance with ASTM C473 where applicable. 2Lengths normally stocked are 8’, 10’, and 12’. Special lengths up to 14’ may be available with lead times and minimum runs that vary by plant. 3Tested in accordance with ASTM C518. 4Represents approximate weight for design and shipping purposes.

Moisture Resistance
Fire Resistance
Special Applications

DensGlass Gypsum Sheathing Panels
Thickness

½” (12.7 mm)

Width

Nominal: 4′ (1219 mm) ± 1/8″ (3 mm)

Length

standard: 8′ (2440 mm), 9′ (2743 mm), 10′ (3048 mm), ± 1/4″ (6 mm)

Weight

lbs/sq. ft. nominal (kg/m²): 1.9 (9)

Humidified Deflection

<2/8″ (6 mm)1, 3

R Value

°F•ft2•hr/BTU (m2•K/W): .56 (0.099)2

1Tested in accordance with ASTM C473 2Tested in accordance with ASTM C518 (heat flow meter) 3Specified values per ASTM C1177

Moisture Resistance
Fire Resistance
Ease-of-Use
Versatility

DensDeck Gypsum Roof Boards & Cover Board Panels
Thickness

Nominal: 1/4″ (6.4 mm) ± 1/16″ (1.6 mm)

Width

Standard: 4′ (1219 mm) ± 1/8″ (3 mm)

Length

standard: 4′ (1219 mm) AND 8′ (2438 mm) ± 1/4″ (6.4 mm)

Weight

lbs/sq. ft. nominal (kg/m²): 1.2 (5.9)1

Flexural Strength

parallel, lbf. Min. (N) ≥40 (178)2

R Value

°F•ft2•hr/BTU (m2•K/W): .283

1Represents approximate weight for design and shipping purposes. Actual weight may vary based on manufacturing location and other factors. 2Tested in accordance with ASTM C473, method B. 3Tested in accordance with ASTM C518 (heat flow meter).

Fire Resistance
Hail Resistance
Wind Resistance
Special Applications

DensDeck Prime roofing side
Thickness

Nominal: 1/4″ (6.4 mm) ± 1/16″ (1.6 mm)

Width

Standard: 4′ (1219 mm) ± 1/8″ (3 mm)

Length

Standard: 4′ (1219 mm) AND 8′ (2438 mm) ± 1/4″ (6.4 mm)

Weight

lbs/sq. ft. nominal (kg/m²): 1.2 (5.9)1

Flexural Strength

Parallel, lbf. Min. (N) ≥40 (178)2

R Value

°F•ft2•hr/BTU (m2•K/W): .283

1Represents approximate weight for design and shipping purposes. Actual weight may vary based on manufacturing location and other factors. 2Tested in accordance with ASTM C473, method B. 3Tested in accordance with ASTM C518 (heat flow meter).

Fire Resistance
HAIL RESISTANCE
WIND RESISTANCE
SPECIAL APPLICATIONS