Fire-Rated Type C Gypsum Board ToughRock FireGuard C
Fire-Rated Gypsum Board Type C ToughRock FireGuard
DensGlass Shaftliner Reinforced Fire-Rated Fiberglass Wall Panels
toughrock drywall wallboard panels

ToughRock® Fireguard C Gypsum Board

  • UL Classified Type TG-C
  • Designed for a variety of UL assemblies with a designated fire-resistant rating1
  • Reinforced with glass fibers to increase strength and fire resistance

1Consult UL Fire Resistance Directory for assembly information.

Give your interior wall and ceiling construction the protection of a UL classified Type TG-C fire resistance rating.

Noncombustible (as described and tested in accordance with ASTM E136) ToughRock® Fireguard C® Gypsum Board is designed for use in a variety of interior drywall applications for wall and ceiling construction in assemblies with a designated fire-resistant rating.1 Its dimensionally stable gypsum core is reinforced with glass fibers, increasing its strength and fire resistance. ToughRock Fireguard C Gypsum Board is manufactured to meet ASTM C1396 Section 5. The 1/2″ (12.7 mm) ToughRock Fireguard C is UL Type TG-C and ULC classified Type C. The 5/8″ (15.9 mm) ToughRock Fireguard C is UL Type TG-C and ULC classified Type C.

1Consult UL Fire Resistance Directory for assembly information.

*FIRE SAFETY CAUTION – Passing a fire test in a controlled laboratory setting and/or certifying or labeling a product as having a one-hour, two-hour, or any other fire resistance or protection rating and, therefore, as acceptable for use in certain fire rated assemblies/systems, does not mean that either a particular assembly/system incorporating the product, or any given piece of the product itself, will necessarily provide one-hour fire resistance, two-hour fire resistance, or any other specified fire resistance or protection in an actual fire. In the event of an actual fire, you should immediately take any and all actions necessary for your safety and the safety of others without regard for any fire rating of any product or assembly/system. For additional information concerning fire ratings and fire safety, visit our Product Fire, Safety and Use Information page.

Fire Resistance

Enhanced fire resistance – UL Classified Type TG-C

SPECS

Physical Properties – 5/8" Board
Thickness

nominal inches: 5/8″ (15.9 mm), ±1/64″ (0.4 mm)

Width

nominal: 4′ (1220 mm) ±3/32″ (2.4 mm)

Length

standard: 8′ (2440 mm) to 14′ (4270 mm), ±1/4″ (6.4 mm)

Weight

lbs./sq. ft., nominal (kh/m²): 2.3 (11.2)1

R Value

ft2•°F•hr/BTU (m2•K/W): 0.56 est. (0.10)

1Represents approximate weight for design and shipping purposes. Actual weight may vary depending on manufacturing location and other factors.

Physical Properties – 1/2" Board
Thickness

nominal inches: 1/2″ (12.7 mm), ±1/64″ (0.4 mm)

Width

nominal: 4′ (1220 mm) ±3/32” (2.4 mm)

Length

standard: 8′ (2440 mm) to 14′ (4270 mm), ±1/4″ (6.4 mm)

Weight

lbs./sq. ft., nominal (kg/m²): 2.0 (9.0)1

R Value

ft2•°F•hr/BTU (m2•K/W): 0.48 est. (0.08)

1Represents approximate weight for design and shipping purposes. Actual weight may vary depending on manufacturing location and other factors.

Warranty / Certifications
GREENGUARD Gold Certification

Certifications may vary by production location, please contact local representative for more information.

Product Resources

Submittals
Warranties
Tech Guides
Safety Data
Installation
Sustainability

Product FAQs

Should the ToughRock Fireguard C gypsum board be installed vertically or horizontally?
Answer

While gypsum boards are stronger in one direction, for walls, they may be installed either vertically or horizontally on both wood and steel studs. If the boards are to be used in a fire rated assembly, then use the board orientation that is stated in your specific rated assembly.

What should we do if the gypsum board gets wet?
What is the fire rating of ToughRock® Fireguard C® Gypsum Board?
How often is a control joint required?

Related Products